Place of Origin: | China |
---|---|
Brand Name: | AI |
Certification: | ISO9001 |
Model Number: | KFZ |
Minimum Order Quantity: | 1 set Transformer No Load Loss Testing Equipment |
Price: | Negotiable |
Packaging Details: | Transformer No Load Loss Testing Equipment Packed in veneer case |
Delivery Time: | 15 days |
Payment Terms: | Western Union, T/T, L/C |
Supply Ability: | 100 sets each month |
Function: | Transformer Load Tester, Load Loss, No Load Loss Testing Equipment | Test Parameters: | Transformer Capacity, No-load Current, No-load Loss, Short Circuit Voltage, Short Circuit (load) Loss |
---|---|---|---|
Capacity Test Range: | 30kVA~3150kVA | Size: | 400×300×220mm |
Weight: | 8kg (Excluding Accessories) | Power Supply: | 220V, 50Hz |
Warranty: | 1 Year | Color: | Black |
Highlight: | Transformer Load Testing Equipment,Transformer No Load Testing Equipment,Load Loss Testing Equipment |
Introduction:
Transformer No Load Loss Testing Equipment is specializing in basic electricity, power users adverse tax evasion problems and developed a new instrument to increase design.
High precision instrument for measuring characteristic parameters of transformer capacity, no-load and load.
Transformer No Load Loss Testing Equipment is a multi-function measuring instrument, which is equivalent to the usual two kinds of test instruments: the transformer capacity tester + transformer characteristic parameter tester.
The utility model can precisely measure a series of power frequency parameters of a plurality of transformers, such as the capacity, the type, the no-load current, the no-load loss, the short circuit (load) loss and the impedance voltage.
Specifications of Transformer No Load Loss Testing Equipment:
1 | Test Parameters |
Transformer capacity, no-load current, no-load loss, short circuit voltage, short circuit (load) loss |
|
2 | Working power | Input voltage | 185Vac~250Vac |
Allowable input voltage | 85Vac~264Vac | ||
Frequency | 50/60Hz | ||
Allowable frequency | 45Hz~65Hz | ||
Input power | 40VA | ||
Joint | Standard AC socket 60320 | ||
3 | AC voltage | Range | 10~650V |
Resolution | 0.001V | ||
Accuracy | 0.2%±0.001V | ||
4 | AC Current | Range | 0.5~60A |
Resolution | 0.001A | ||
Accuracy | 0.2%±0.001A | ||
5 | Frequency | Range | 45Hz~65Hz |
Resolution | 0.001Hz | ||
Accuracy | 0.2%±0.001Hz | ||
6 | Power | Range | 0~39kW |
Resolution | 0.001kW | ||
Accuracy |
<±0.5%(CosΦ>0.1) ±1.0%(0.02<CosΦ<0.1) |
||
7 | Capacity test range | 10kV Dry type transformer | 30kVA~3150kVA |
10kV Oil immersed transformer | 30kVA~3150kVA | ||
35kV Oil immersed transformer | 50kVA~31500kVA | ||
20kV Dry type transformer | 50kVA~2500kVA | ||
35kV Dry type transformer | 50kVA~2000kVA | ||
8 | Environment | Operating temperature | -10℃~+50℃ |
Storage temperature | -25℃~+70℃ | ||
Relative humidity | 5%~95% | ||
9 | Size | 400×300×220mm3 | |
10 | Weight | ≈8kg (Excluding accessories) |