Place of Origin: | CHINA |
---|---|
Brand Name: | AI |
Certification: | ISO |
Model Number: | AIC-60112 |
Minimum Order Quantity: | 1 SET Comparative Insultion Tracking Index Tester |
Price: | Negotiable |
Packaging Details: | Comparative Insultion Tracking Index Tester packed in Plywood case |
Delivery Time: | 30 days |
Payment Terms: | Western Union, T/T, L/C |
Supply Ability: | 100 Sets per Month |
Test Standard: | IEC60112, ASTM D3638-12,UL746A | Electrode Pressure: | 1.0 ± 0.05N |
---|---|---|---|
Electrode Distance: | 4.0mm ± 0.01mm, The Angle 60 ° ± 5 | Test Voltage: | 0 ~ 1000V Adjustable |
Dropping Height: | 30 ~ 40mm Adjustable | Warranty: | 1 Year |
Keyword: | Comparative Tracking Index Tester | Dropping Time: | 30s ± 5s |
Highlight: | Tracking Index Tester,Comparative Tracking Index Tester,ASTM D3638-12 |
The tracking index tester is designed according to GB4207 and IEC60112. It is suitable for lighting, low voltage electrical equipment, household appliances, electrical machines, motors, power tools, electronic equipment , electrical instruments. It also applies for insulation, plastic, electrical connectors, accessories industry.
Method for the determination of the proof and the comparative tracking indices of solid insulating materials . It is simple, accurate, reliable, and practical features.
Standard:
UL746A:(CTI) Comparative Tracking Index or Insulation Tracking Electrical Test
Feature:
1.The combustion chamber paint treatment; nice, corrosion-resistant; dimensions: 1200mm X 600mmx 1200mm;
2. All sample holders are made of stainless steel;
3. The (CTI) Low Voltage Comparative Insultion Tracking Index Tester consists of voltmeter, ammeter, time overcurrent relays, power supplies, circuit control system, push button switches, lights and other components;
4. Automatic drip device includes dropping tube, drip nozzle, counting means counting device drip, drip control device, dropping the volume measuring tools;
5. Drip nozzle device can be adjusted; adjust the height of 30-40mm; ensure dripping position in the middle of the two electrodes;
6. The electrode means comprises platinum electrode, the electrode fixtures, 4mm gauge, etc., the electrode can be adjusted, removable;
7. Electrode width 5mm, thickness 2mm, 99.9% purity platinum, 30 to 60 degrees tip;
8. The electrode sample pressure adjustable, adjustable range (1.00N ± 0.001N); electrode distance 4.0mm ± 0.01mm, the angle 60 ° ± 5 °;
9. (CTI) Low Voltage Comparative Insultion Tracking Index Tester is supplied with the sample stage;
10.The glass: Thickness ≥4mm;
11. The testing equipment is supplied with electrolyte: sodium chloride and alkyl naphthalene sulfonic acid reagent each bottle.
Safety control system:
1.The test voltage: 0 ~ 1000V adjustable
The maximum error of voltmeter displays : 1%;
2. Short-circuit current: (1 Guests 0. 1) A,the voltage drop value does not exceed 10%
3. The test current exceeds 0.5A duration of more than two seconds, the system automatically shut down equipment;
4.Security door control system; the door opens, the test system is not working;
5.The electrode: 5mm × 2mm rectangular platinum electrode and brass electrode of each pair meet size requirements of IEC60112 Figure B.1;
6.The electrode: the angle formed between the electrodes is 60 ° disabilities 5 °, a pitch of (4 Soil 0.1mm);
7.The electrode: the sample pressure: 1 00N disabilities 0.05N;.
8.Drip system: (30 ± 5) seconds (on time 29.8S + open drip drip duration 0.2S) automatic counting, digital display (can be preset), 50 drops of time: (24.5 Soil 2) min;
9.Drip systems: a drop of fluid needle tip to the sample surface height: 35mm disabilities 5mm (attach a gauge for measuring your reference);
10.Drip systems: drip Weight: 20 drops: 0.380g ~ 0.489g; 50 drops:.. 0 997g ~ 1 147g;
11.PLC with touch screen control system; to achieve test smarter, more convenient has been operated.
12.The test data is automatically recorded, automatic storage, free retrieval;
Specification:
1 | Electrode material | electrode tip - platinum metal (platinum) |
2 | Electrode pressure | 1.0 ± 0.05N |
3 | Electrode distance | 4.0mm ± 0.01mm, the angle 60 ° ± 5 |
4 | Electrode voltage | 100 ~ 600V (48 ~ 60HZ) adjustable, short-circuit current 1.0 ± 0.1A of less than 10% |
5 | Dropping height | 30 ~ 40mm adjustable |
6 | Dropping size | 44 ~ 55 drops / 1cm3 adjustable |
7 | Dropping time | 30s ± 5s, |
8 | Dropping times | 0 ~ 9999 times available |
9 | Leakage judgment | when loop current is greater than 0.5A and maintaining for 2 seconds,the relay cut off the current and result indicates sample failed |
10 | Testing process | automatic control, independent ventilation |
11 | Applicatable standard | IEC60112, ASTM D3638-12,UL746A |
12 | Inside Volume | 0.1 m³ (Can be customized 0.5 m³ or 0.75 m³) |
13 | Overal dimension | 630mm width x390mm depth x750mm height |