Place of Origin: | CHINA |
---|---|
Brand Name: | AI |
Certification: | ISO |
Model Number: | SIT |
Minimum Order Quantity: | 1 SET Single Flame Source Test Apparatus |
Price: | negotiable |
Packaging Details: | Single Flame Source Test Apparatus packed in Plywood case |
Delivery Time: | 30 days |
Payment Terms: | Western Union, T/T, L/C |
Supply Ability: | 100 Sets per Month |
Test Standard: | EN ISO 11925-2,DIN 53438,EN 13501,IEC 61730-2:2016 | Size: | 850 Mm (W) X 450 Mm (D) X 800 Mm (H) |
---|---|---|---|
Weight: | 24KG | Warranty: | 1 Year |
Mateiral: | Corrosion Resistant Stainless Steel | Anemometer: | 0-10 M/s |
Pressure Reducing Valve: | Between 10 KPa And 50 KPa | Sample Holder: | 3 Types |
Highlight: | Single Flame Source Test Apparatus,Ignitability Apparatus EN ISO 11925-2,Ignitability Apparatus DIN 53438 |
Small Flame Ignition Tester is designed in accordance with DIN 53438 & ISO 11925-2:Testing of combustible materials; response to ignition by a small flame, with surface ignition and edge ignition.
The combustion chamber is made from corrosion resistant stainless steel, to maximize operating life.
It has large front and side doors for easy access. These are glazed with toughened glass for full view of the specimen during a test.
An extensively adjustable burner assembly, mounted on runners, to enable the small premixed flame to be tilted at an angle of 45 degree to the specimen and offered to it in one fluid movement.
Specimen holder capable of housing the specimens up to and including 60 mm thick.
A fully adjustable specimen support frame facilitating lateral movement of the specimen holder so that the flame can be applied either at the specimen centre position, or at laterally spaced points.
Spares available:
Multilayer specimen holder
Loose fill specimen holder
Anemometer 0-10 m/s range
Timing device with 0.2 sec divisions
Pressure reducing valve: Between 10 kPa and 50 kPa
Electrical | 110V AC 60Hz / 230V AC 50Hz, 10A |
Ambient Temperature | 10°C to 35°C |
Dimensions | 850 mm (W) X 450 mm (D) X 800 mm (H) |
Weight | 24KG |
Applicable standards | EN ISO 11925-2,DIN 53438,EN 13501,IEC 61730-2:2016 |
Gas | Propane with a minimum purity of 95%. |
Above Picture is Instrument Sent to USA in 2019