| Place of Origin: | China |
|---|---|
| Brand Name: | AI |
| Certification: | ISO |
| Model Number: | CPT-3 |
| Minimum Order Quantity: | 1 Set Current Transformer Test Instrument |
| Price: | Negotiable |
| Packaging Details: | Current Transformer Test Instrument packed in Plywood case |
| Delivery Time: | 15 days |
| Payment Terms: | T/T, Western Union, L/C |
| Supply Ability: | 100000 sets per month |
| Power Supply: | AC220V±10%, 50/60Hz±10% | Display: | LCD |
|---|---|---|---|
| Keyword: | CT Analyzer Current Transformer Tester | Standard: | EC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13 |
| Measuring Range: | 0~200V | Current Measurement: | 0~10A |
| Turns Ratio Measurement Range: | 1-35000 | Coil Resistance Measurement: | 0~80Ω |
| Highlight: | CT Analyzer,Current Transformer Test Instrument,IEC 60044 |
||
Current Transformer CT Analyzer CT Testing Equipment
Tester for current transformer:
Applications of CT Current Transformer Tester:
Specifications:
| Item Name | CT Current Transformer Tester | |
| Test standards | IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13 | |
| Power supply | AC220V±10%, 50/60Hz±10% | |
| Voltage output | 0.1~125V (AC) | |
| Current output | 0.001~5A(RMS) | |
| Power output | 300VA | |
| Max. knee voltage measurement | 45KV | |
| Current measurement | Range | 0~10A (automatically change range in 0.1/0.4/2/10A) |
| Error | <±0.1%+0.01%FS | |
| Voltage measurement | Range | 0~200V (automatically change range in 1V/10V/70V/200V) | |
| Error | < ±0.1%+0.01%FS | ||
| Turns ratio measurement Range | 1~35000 1~2000, error<0.05% 2000~5000,error<0.1% 5000~35000,error<0.2% |
||
| Phase measurement | error | ±2min | |
| resolution | 0.01min | ||
| Coil resistance measurement | Range | 0~80Ω (automatically change range in 2ohm/20ohm/80ohm) | |
| Error | < 0.2%RDG+0.02%FS | ||
| Maximum resolution : 0.1mΩ | |||
| Temperature measurement | -50~100 Celsius degree; error<3 Celsius degree | ||
| CT Secondary burden | Range | 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm) | |
| Error | <0.2%RDG+0.02%FS | ||
| Maximum resolution : 0.001ohm | |||
| Memory capacity | >1000 groups test results | ||
| Working condition temperature | -10℃~50℃; moist ≤90% |
||
![]()