Place of Origin: | China |
---|---|
Brand Name: | AI |
Certification: | ISO9001 |
Model Number: | 4530F |
Minimum Order Quantity: | 1 set Atomic Absorption Spectrophotometer |
Price: | Negotiable |
Packaging Details: | Atomic Absorption Spectrophotometer packed in veneer case. |
Delivery Time: | 30 days |
Payment Terms: | Western Union, T/T, L/C |
Supply Ability: | 100 sets each month |
Function: | Metal Element Analysis | Lamp Turrents: | 8 |
---|---|---|---|
Control Method: | Computer Control | Wavelength Range: | 190 – 900nm |
Spectral Bandwidth: | 0.1nm, 0.2nm, 0.4nm, 1.0nm And 2.0nm | Grating: | 1800 Lines/mm |
Inflamer: | All-metal Titanium Burner | Atomizer: | Effective Glass Atomizer |
Size: | 700mm×550mm×450mm | Weight: | 75kg |
Highlight: | Flame Atomic Absorption Spectrophotometer,900nm Atomic Absorption Spectrophotometer,Atomic Absorption Spectrophotometer |
Flame Atomic Absorption Spectrophotometer
Features:
Specifications of 4530F Atomic Absorption Spectrophotometer :
Wavelength range | 190 – 900nm |
Spectral bandwidth | Can automatically change between 0.1nm, 0.2nm, 0.4nm, 1.0nm and 2.0nm |
Accuracy of the wavelength | ±0.15nm |
Receptivity of the wavelength | ≤0.04nm |
Base line stability | ≤0.002A/30min (Cu) |
Characteristic viscosity | 0.02μg/ml/1% (Cu) |
Checking limit | 0.004μg/ml (Cu) |
Preciseness | 0.5% |
Grating | 1800 lines/mm |
Inflamer | All-metal titanium burner |
Atomizer | Effective glass atomizer |
Lamp stand | Eight lamps |
D2 background correction ability | When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method |
Size and weight | 700mm×550mm×450mm 75Kg |
Power source | 220V±22V AC |
Flame System:
Acetylene air burner | 100mm |
Nitrous oxide acetylene flame head | 50mm |
Ignition dynamic baseline drift | ≤0.006A/30min |
(Cu) Characteristic viscosity | ≤0.025μg/ml/1% |
Related standard deviation of the accuracy | ≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml) |
Safety system | Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner |
Optional Graphite Furnace:
The highest temperature | 3000℃ |
The largest temperature rising speed | ≥2000℃/S |
Characteristic quantity | Cd≤0.5×10-12g Cu≤0.5×10-11g |
Accuracy | Cu≤3% Cd≤3% |
Size and weight | 550mm×450mm×300mm 65Kg |
Safety system | Over current protection |
Protection | Low air pressure alarm, low cooling water flow alarm |
Power source and power | 220V±22V AC 7000W |